Neonatal and pediatric central venous catheter in polyurethane for short and medium duration peripheral access, radiopaque, for parenteral nutrition and drug administration.
Nutriline PICC 2 fr
Neonatal and pediatric central venous catheter in polyurethane for short and medium duration peripheral access, radiopaque, for parenteral nutrition and drug administration.
Related products
-
C-PAP Bousignac
Respiratory assist device for spontaneously ventilating patients. This device allows to maintain a higher pressure in the airways than atmospheric pressure throughout the respiratory cycle. The CPAP ventilation mode allows: – Recruit collapsed alveoli; – Restore a satisfactory level of functional residual capacity; – Improve the exchange of gases at the level of the capillary alveolus membrane – Decrease pulmonary resistance; – Reduce the effort to breathe; – Redistribute the alveolar fluid to the interstitial space in case of acute pulmonary edema The Boussignac CPAP device and its connector for manometer constitute a device that is connects to a face mask via a 22mm male connector, ribbed top open to air
-
Bujia Bousignac Intercambiador de Tubo 5576
Orotracheal guide for difficult intubation with oxygen injection and oxygen connector. The Boussignac spark plug has two channels. The first transparent channel is closed proximally and open distally. The second channel, green, blue or pink, is open proximally and closed distally.
-
Vystar Manifold Llave de 3 Vias
Biovystar / Vystar ramp of stopcocks is an add-on device for intravenous catheters comprising: a body molded in a lipid-resistant raw material (polycarbonate) and transparent to detect air bubbles to facilitate the priming of the device. stopcocks in polyoxymethylene (POM), each stopcock having a different colour.
-
Microflash Introductor para PICC
Peelable cannula introducer for the insertion of neonatal catheters type PICC 2 fr with needle, with a side hole for the rapid detection of blood reflux transparent cannula. The triple-bevel guide wire, for a smooth and non-traumatic introduction and a side hole located near the bevel, to quickly verify the correct placement of the catheter in the vein The transparent cannula with radiopaque line, allows immediate visualization of the blood during penetration into the vein, thus avoiding any trauma to the vessel and minimizing blood loss. Ventilation cap on needle canopy to minimize blood loss Grooved fins to help prevent fingers from slipping when cannula is divided.
Reviews
There are no reviews yet.